-40%

Hydraulic Directional Control Solenoid Valve D03 (NG6) 21 GPM AC or DC 3Position

$ 52.27

Availability: 255 in stock
  • Return shipping will be paid by: Buyer
  • Item must be returned within: 30 Days
  • MPN: 6181353259185
  • Brand: Fluidhaus
  • Condition: New
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back

    Description

    Hydraulic Directional Control Valve
    D03 (NG6) Cetop mounting.  Can be mounted to standard available subplates and bar manifolds.
    Maximum flow of 21 gpm for DC power and 15.8 gpm for AC (reference Solenoid Power limit chart)
    Maximum working pressure = 4560psi (315 Bar)
    3-position, 4-way, Spring centered, energize to shift
    Double solenoid operated
    Removable Coil
    Valve can be mounted in any direction
    Coil can be rotated to optimal connector position
    Uses DIN 46350 Form A electrical connection type
    Includes lighted DIN connector for each coil.  LED illuminate’s clear connector housing when power is supplied to the connector/coil.  IP65 rating
    NBR Buna Seals
    Four fastening screws included, M5x45mm long
    White label with no logo for OEM manufacturers.
    Weight = 4.3 lbs (1.95 kg)
    Completed data sheet available at the following link:
    Catalog
    Options:
    Solenoid Voltage:
    12VDC, 24VDC, 110VAC (50 or 60 hz), 220VAC (50 or 60 hz)
    Spool Configurations:
    C:
    Closed center spool, all ports blocked when centered.
    Useful to switch actuator directions and to fully stop cylinder or motor when centered.  Make sure there is a relief valve to protect overrunning loads from spiking the pressure during sudden stops when centering.  Note that there is some leakage of oil across the spool in the center position and slow drifting of the actuator could be possible.
    M
    :  Motor spool, A and B ports to tank and P port blocked when centered.
    Actuators will move freely from external forces when the valve is in the center position.  Motors and cylinders will coast to a stop when centering.  Adding an A&B port P.O. check valve under this valve will ensure a positive stop and hold the position of a motor and cylinder for longer durations than with just a closed center spool valve C.
    T
    :  Tandem Spool, A and B ports closed and P to T in center position:
    Actuators will stop in center position and the supply pressure will be directed to tank.  Commonly used with fixed displacement gear pumps so pressure can flow direct to tank and not build up heat by blowing across a relieve valve as would be needed with the M and C spool.
    H:
    Open Center Spool, A, B P and T ports connected in center.
    Actuators will freely move when valve is de-energized, and spring centered.  Pressure and all ports will drain to tank.  Energize solenoid “a” and “b” to change direction of actuator.
    High volume OEM series production available per request.